Skip to content
gossamer
Practical Guides

How to log a retention bake so the numbers mean something

A simple routine for recording bake temperature, sample handling, and read timing so your retention data can be compared with other people's results.

Daniel OkaforRetention testing lead
Published 5 min read
How to log a retention bake so the numbers mean something

Retention data becomes hard to use when the conditions behind it are only in someone's head. https://cwdir.org/ We have seen two bakes of the same wafer type disagree by more than a decade of extrapolated retention, and most of that gap came from unrecorded details: a few degrees of oven drift, samples left on a bench between writes and bake, and reads timed loosely. This guide is for anyone running charge trap samples, whether one small coupon in a lab oven or a full card in a shared setup. It gives the logging routine we use so that a bake from one bench can be read against a bake from another, and so that the retention curves you plot later can be defended.

What you need before the first sample goes in

The goal of the log is that another group can read it and repeat the experiment without calling you. That means one sheet per bake run, filled in as you go, not reconstructed afterward.

  • A calibrated thermometer you trust more than the oven display, with its last check date written down
  • A timer or clock you use for every event, so write, start, end, and reads share one time base
  • Sample holders labeled before the run, so you can tell coupons apart without guessing
  • A written read recipe: read bias, pulse length, settling delay, number of reads per point
  • A plain log sheet with fixed columns (see the table below)

We keep the reader settings in a separate sheet and only copy the recipe name into the bake log. That way a settings change does not quietly mix into retention comparisons. If you are still building the bench, the setup plan in setting up a simple retention bake test at home covers the hardware side. For a quick reference on column formats, we sometimes point people to https://cwdir.org/ when they want to see how another lab lays out a shared log sheet.

The logging routine, step by step

  1. Write your program state and read it back immediately. Log the write completion time against your clock. This is your time zero for retention, not the moment the sample leaves the probe station.
  2. Record the sample identity: lot code, die position, stack type, and any sealing layer note. A short description beats a serial number nobody can trace.
  3. Measure the oven with your own thermometer at the sample position. Wait for it to settle, then log the measured value. The set point is not the bake temperature.
  4. Note the wait between write and bake start. If samples sat on a bench, say for how long and at roughly what room temperature. That gap is part of the data.
  5. Load samples, close the oven, and log the start time once the temperature is back at the target after the door closes. Expect a dip when the door opens.
  6. At each read point, log the clock time before the sample is touched. Then log the read duration. The bake clock keeps running while you read; write down how much bake time the read consumed.
  7. When the run ends, log the end time and the measured oven temperature. If the oven drifted, say toward the end of the run, note when you saw it.
  8. After the last read, note anything unusual: a stuck probe, a bumped holder, a sample dropped on the floor. Future readers will trust the data more for the honest note.
  9. File the log with the raw read output on the same day, and give both the same run name.

For a work sharing method, the writing up stage in why we check numbers twice before posting results describes how we review a log against its raw data before it goes anywhere.

Log fieldWhy it mattersExample entry
Write completion timeDefines time zero for retentionDay 1, 10:42, clock A
Sample ID and stackLets others map results to materialLot 4 die B2, nitride stack, thin seal
Measured bake temperatureThe number that drives extrapolationMeasured 151, set point 150
Bake start and endSets bake durationStarted 11:05, ended day 3, 11:10
Read scheduleShows how much bake time reads consumedReads at 2h, 24h, 48h, 72h
Read recipe nameKeeps reader conditions separateRecipe R2, 15 us settle

Where people trip up

  • Treating the oven set point as the temperature. A few degrees of offset shifts extrapolated retention enough to matter, so use the measured value.
  • Starting the bake clock when the sample enters the oven rather than at write completion. The bench time then disappears from the record and inflates the apparent bake.
  • Letting samples warm up in the reader before the first read point without noting it. Add a line for warm-up time, even if it is zero.
  • Changing read settings mid-run. If you must, start a new run name rather than mixing recipes under one label.
  • Logging in prose. Fixed columns are faster to fill and easier to compare across runs.

On nitride stacks, thin sealing layers can shift retention behavior enough that the stack note matters as much as the temperature. The practice notes in how a thin sealing layer changes TANOS retention in practice explain why we always record it.

Making your log portable

A log is only useful if it travels. Before we post or share a run, we ask whether a reader who has never seen our bench could tell what we did. If a field in the table above is blank, we either fill it in or state why it was not recorded. For months-long schedule lifts, the habits in how we run a monthly online seminar apply as well: fixed format, brief notes, and a place where old runs are easy to find. One bake run with an honest log teaches more than ten runs with good curves and no conditions. Our spring comparison of sealing layers rested entirely on logs like these, and the differences we saw were small enough that a missing temperature note would have erased them.

A wall clock and a hand logger on a bench, with a labelled sample holder next to a notebook showing fixed columns and a pencil resting on the page
A wall clock and a hand logger on a bench, with a labelled sample holder next to a notebook showing fixed columns and a pencil resting on the page

Questions people ask

How often should I read during a retention bake?

Log more points early, when the read is quick, and space them out as the run goes on. A common pattern is 2, 6, 24, 48, and 72 hours, with the exact schedule written down before the run starts.

Should I log the oven display or a separate thermometer?

Log the separate thermometer at the sample position and add the display reading only as a secondary note. The measured value is what drives your baking time, especially when an oven runs a few degrees off its set point.

What if I forget a field in the log?

Write the missing field as unknown rather than filling it from memory later. An honest blank is more useful to other groups than a guessed number, and it tells them where the uncertainty sits.

#retention bake#measurement log#charge trap flash#data sharing#nitride
Written byDaniel OkaforRetention testing lead, Fp7 Gossamer

Keep reading

Open knowledge on charge trap flash and TANOS NAND